1.
Front Public Health ; 12: 1335560, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38638484

RESUMO

Objective: This study aimed to investigate the knowledge, attitude, and practice (KAP) regarding disinfection and hand hygiene, along with associated influencing factors among childcare facilities staff during the COVID-19 pandemic in Anhui, and to provide information for developing disinfection and hand hygiene strategies for childcare facilities. Methods: A web-based cross-sectional study was conducted among Anhui Province residents in China in September 2020. In this study, 60 childcare facilities in two cities of Anhui Province were selected using the convenient sampling method for questionnaires. The questionnaires were distributed through a web-based platform. The disinfection and hand hygiene KAP scores among childcare facilities staff were calculated, and their influencing factors were analyzed. The accuracy rates of knowledge, attitude, and practice of behavior were calculated and analyzed. Results: A total of 1,029 participants were included in the study. The disinfection and hand hygiene knowledge, attitude and practice ranged from approximately 5 to 23, 1 to 5, 3 to 13, respectively. The score of urban areas was higher than that of rural areas. Higher education levels and more years of working were associated with higher scores. Additionally, staff who received training or supervision had higher scores than those without. The categories with the lowest knowledge accuracy rate (46.3%), lowest attitude accuracy rate (4.2%), and "always" practice rate (5.3%) among childcare facility staff were all related to the question categories concerning the appropriate range of disinfectants for use. The accuracy rates of hand hygiene knowledge and attitude among the childcare facility staff were high (83.7%-99.6%), but the "always" practice rate was in the middle range (63.0%). Conclusion: The disinfection and hand hygiene knowledge among childcare facilities staff was inadequate during the COVID-19 pandemic in Anhui. Continuous implementation of education and training, particularly in rural areas, is essential. Establishing a monitoring system to assess usage effectiveness and adverse reactions in China is critical. Interventions should focus on increasing compliance with hand hygiene practices. Further research should explore the training and intervention of disinfection and hand hygiene, the safety of disinfection measures, and more operational hand hygiene methods in childcare facilities.


Assuntos
COVID-19 , Higiene das Mãos , Criança , Humanos , Higiene das Mãos/métodos , COVID-19/epidemiologia , COVID-19/prevenção & controle , Estudos Transversais , Cuidado da Criança , Desinfecção , Conhecimentos, Atitudes e Prática em Saúde , Pandemias/prevenção & controle
2.
Environ Sci Technol ; 58(15): 6552-6563, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38571383

RESUMO

Extracellular polymeric substances (EPS) ubiquitously encapsulate microbes and play crucial roles in various environmental processes. However, understanding their complex interactions with dynamic bacterial behaviors, especially during the disinfection process, remains very limited. In this work, we investigated the impact of EPS on bacterial disinfection kinetics by developing a permanent EPS removal strategy. We genetically disrupted the synthesis of exopolysaccharides, the structural components of EPS, in Pseudomonas aeruginosa, a well-known EPS-producing opportunistic pathogen found in diverse environments, creating an EPS-deficient strain. This method ensured a lasting absence of EPS while maintaining bacterial integrity and viability, allowing for real-time in situ investigations of the roles of EPS in disinfection. Our findings indicate that removing EPS from bacteria substantially lowered their susceptibility threshold to disinfectants such as ozone, chloramine B, and free chlorine. This removal also substantially accelerated disinfection kinetics, shortened the resistance time, and increased disinfection efficiency, thereby enhancing the overall bactericidal effect. The absence of EPS was found to enhance bacterial motility and increase bacterial cell vulnerability to disinfectants, resulting in greater membrane damage and intensified reactive oxygen species (ROS) production upon exposure to disinfectants. These insights highlight the central role of EPS in bacterial defenses and offer promising implications for developing more effective disinfection strategies.


Assuntos
Desinfetantes , Desinfecção , Desinfecção/métodos , Matriz Extracelular de Substâncias Poliméricas , Desinfetantes/farmacologia , Cloro/farmacologia , Cinética
3.
J Appl Microbiol ; 135(4)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38573833

RESUMO

In the 1940s and 1950s, researchers seeking safe and novel ways to eliminate airborne pathogens from enclosed spaces, investigated glycol vapours as a method of disinfection. More recently, the COVID-19 pandemic highlighted the need for a non-toxic aerial disinfectant that can be used in the presence of people. This scoping review is intended to analyse the early and more recent literature on glycol disinfection, scrutinizing the methodologies used, and to determine if the use of glycols as modern-day disinfectants is justified PRISMA-ScR guidelines were used to assess the 749 articles retrieved from the Web of Science platform, with 46 articles retained after the search strategy was applied. Early studies generally demonstrated good disinfection capabilities against airborne bacteria and viruses, particularly with propylene glycol (PG) vapour. Vapour pressure, relative humidity, and glycol concentration were found to be important factors affecting the efficacy of glycol vapours. Contact times depended mainly on the glycol application method (i.e. aerosolization or liquid formulation), although information on how glycol efficacy is impacted by contact time is limited. Triethylene glycol (TEG) is deemed to have low toxicity, carcinogenicity, and mutagenicity and is registered for use in air sanitization and deodorization by the US Environmental Protection Agency. Glycols are also used in liquid formulations for their antimicrobial activity against a wide range of microorganisms, although when used as a non-active excipient in products, their contribution to antimicrobial efficacy is rarely assessed. The appropriate use of liquid glycol-containing formulations was found to positively impact the antimicrobial capabilities of disinfectants when used at temperatures <0, food preservatives, and dental medicaments. Providing modern delivery technology can accurately control environmental conditions, the use of aerosolized glycol formulations should lead to successful disinfection, aiding infection prevention, and control regimens.


Assuntos
Anti-Infecciosos , Desinfetantes , Humanos , Pandemias/prevenção & controle , Desinfetantes/farmacologia , Desinfecção/métodos , Anti-Infecciosos/farmacologia , Propilenoglicol/farmacologia , Gases
4.
Environ Sci Technol ; 58(15): 6793-6803, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38574343

RESUMO

Current disinfection processes pose an emerging environmental risk due to the ineffective removal of antibiotic-resistant bacteria, especially disinfection residual bacteria (DRB) carrying multidrug-resistant plasmids (MRPs). However, the characteristics of DRB-carried MRPs are poorly understood. In this study, qPCR analysis reveals that the total absolute abundance of four plasmids in postdisinfection effluent decreases by 1.15 log units, while their relative abundance increases by 0.11 copies/cell compared to investigated wastewater treatment plant (WWTP) influent. We obtain three distinctive DRB-carried MRPs (pWWTP-01-03) from postdisinfection effluent, each carrying 9-11 antibiotic-resistant genes (ARGs). pWWTP-01 contains all 11 ARGs within an ∼25 Kbp chimeric genomic island showing strong patterns of recombination with MRPs from foodborne outbreaks and hospitals. Antibiotic-, disinfectant-, and heavy-metal-resistant genes on the same plasmid underscore the potential roles of disinfectants and heavy metals in the coselection of ARGs. Additionally, pWWTP-02 harbors an adhesin-type virulence operon, implying risks of both antibiotic resistance and pathogenicity upon entering environments. Furthermore, some MRPs from DRB are capable of transferring and could confer selective advantages to recipients under environmentally relevant antibiotic pressure. Overall, this study advances our understanding of DRB-carried MRPs and highlights the imminent need to monitor and control wastewater MRPs for environmental security.


Assuntos
Desinfetantes , Purificação da Água , Desinfecção , Genes Bacterianos , Bactérias/genética , Antibacterianos/farmacologia , Desinfetantes/farmacologia , Plasmídeos/genética
5.
Appl Microbiol Biotechnol ; 108(1): 286, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38578301

RESUMO

Ultraviolet-C light-emitting diodes (UV-C LEDs) are an emerging technology for decontamination applications in different sectors. In this study, the inactivation of bacterial biofilms was investigated by applying an UV-C LED emitting at 280 nm and by measuring both the influence of the initial cell density (load) and presence of an extracellular matrix (biofilm). Two bacterial strains exposing diverging matrix structures and biochemical compositions were used: Pseudomonas aeruginosa and Leuconostoc citreum. UV-C LED irradiation was applied at three UV doses (171 to 684 mJ/cm2) on both surface-spread cells and on 24-h biofilms and under controlled cell loads, and bacterial survival was determined. All surface-spread bacteria, between 105 and 109 CFU/cm2, and biofilms at 108 CFU/cm2 showed that bacterial response to irradiation was dose-dependent. The treatment efficacy decreased significantly for L. citreum surface-spread cells when the initial cell load was high, while no load effect was observed for P. aeruginosa. Inactivation was also reduced when bacteria were grown under a biofilm form, especially for P. aeruginosa: a protective effect could be attributed to abundant extracellular DNA and proteins in the matrix of P. aeruginosa biofilms, as revealed by Confocal Laser Scanning Microscopy observations. This study showed that initial cell load and exopolymeric substances are major factors influencing UV-C LED antibiofilm treatment efficacy. KEY POINTS: • Bacterial cell load (CFU/cm2) could impact UV-C LED irradiation efficiency • Characteristics of the biofilm matrix have a paramount importance on inactivation • The dose to be applied can be predicted based on biofilm properties.


Assuntos
Biofilmes , Desinfecção , Matriz Extracelular , Bactérias , Matriz Extracelular de Substâncias Poliméricas , Pseudomonas aeruginosa
6.
BMC Oral Health ; 24(1): 416, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38580975

RESUMO

OBJECTIVE: To investigate the status and related factors of sterilizers in dental health-care settings in Yunnan Province, with the aim of providing a theoretical basis for the health administrative department to formulate regional quality control programs and systems, proposing reasonable suggestions for optimizing the allocation of sterilizer resources in Yunnan's dental health-care settings, thereby improving resource utilization efficiency. METHODS: This cross-sectional survey was conducted in 2600 dental health-care settings in Yunnan Province in March 2020. Uni-variable linear regression, multi-variable linear regression, curve fitting and threshold effect analysis were used to understand the relationship between dental units and sterilizers. RESULTS: A total of 2600 dental health-care settings were included. The disinfection and sterilization work were mainly completed by the dental department in 1510(58.1%) institutions. 44(1.7%) institutions were not allocated sterilization equipment, and 1632 (62.8%) had only one sterilizer. The median allocation of sterilizers was 1.0. Uni-variable linear regression showed significant differences in covariates such as dental unit, dental handpiece, disinfection equipment, dentist, and dental assistant, which were more sensitive (p < 0.001) and statistically significant. The adjusted model was more stable in the multi-variable linear regression, and the differences in covariates between different settings were statistically significant. Curve fitting revealed an S-shaped curvilinear relationship between the number of dental units and sterilizers in oral healthcare settings. CONCLUSION: The disinfection and sterilization work was mainly completed by the dental department in dental health-care settings in Yunnan Province. Sterilizer allocation increases with the number of dental units, but some institutions have insufficient allocation of sterilizer and manpower resources, resulting in certain risks of infection control. Thus, it is necessary to strengthen supervision, inspection and regional quality control work in infection control of dentistry.


Assuntos
Desinfecção , Controle de Infecções , Humanos , Estudos Transversais , China , Instrumentos Odontológicos
7.
Oral Health Prev Dent ; 22: 151-158, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38652288

RESUMO

PURPOSE: To investigate the effect of full-mouth disinfection on the sizes of the periodontal wound and periodontal inflammatory burden and whether it leads to a decrease in C-reactive protein (CRP) levels. MATERIALS AND METHODS: The study included 20 systemically healthy subjects (11 women and 9 men) 30 to 68 years old with localised or generalised periodontitis (stage III, grade C). The sizes of the periodontal wound and periodontal inflammatory burden were measured with the web application "Periodontalwound", which is based on measurements of average tooth cervices, as well as probing depths and bleeding on probing assessed at six sites around each tooth present in the oral cavity. The levels of hsCRP (high-sensitivity CRP) were measured with an immunochemical method. All three parameters were measured before initial treatment and 3 months after therapy. Full-mouth disinfection included removal of plaque and calculus with ultrasonic and hand instruments in one session. RESULTS: The results showed a statistically significant decrease in the size of the periodontal wound (p < 0.001), a statistically significant decrease in the size of periodontal inflammatory burden (p < 0.001), and a decrease in hsCRP levels 3 months after therapy. CONCLUSION: Full-mouth disinfection leads to a decrease in the periodontal wound and periodontal inflammatory burden size, as well as a decrease in the levels of hsCRP in patients with localised or generalised periodontitis (stage III, grade C).


Assuntos
Proteína C-Reativa , Desinfecção , Humanos , Masculino , Feminino , Proteína C-Reativa/análise , Pessoa de Meia-Idade , Adulto , Idoso , Desinfecção/métodos , Periodontite , Índice Periodontal , Placa Dentária , Cálculos Dentários , Bolsa Periodontal , Terapia por Ultrassom/métodos
8.
J Hazard Mater ; 470: 134254, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38615644

RESUMO

The existence of antibiotic resistant bacteria (ARB) and antibiotic resistance genes (ARGs) has been a global public environment and health issue. Due to the different cell structures, gram-positive/negative ARB exhibit various inactivation mechanisms in water disinfection. In this study, a gram-negative ARB Escherichia coli DH5α (E. coli DH5α) was used as a horizontal gene transfer (HGT) donor, while a gram-positive ARB Bacillus as a recipient. To develop an efficient and engineering applicable method in water disinfection, ARB and ARGs removal efficiency of Fe(VI) coupled peroxydisulfate (PDS) or peroxymonosulfate (PMS) was compared, wherein hydroxylamine (HA) was added as a reducing agent. The results indicated that Fe(VI)/PMS/HA showed higher disinfection efficiency than Fe(VI)/PDS/HA. When the concentration of each Fe(VI), PMS, HA was 0.48 mM, 5.15 log E. coli DH5α and 3.57 log Bacillus lost cultivability, while the proportion of recovered cells was 0.0017 % and 0.0566 %, respectively, and HGT was blocked. Intracellular tetA was reduced by 2.49 log. Fe(IV) and/or Fe(V) were proved to be the decisive reactive species. Due to the superiority of low cost as well as high efficiency and practicality, Fe(VI)/PMS/HA has significant application potential in ARB, ARGs removal and HGT inhibition, offering a new insight for wastewater treatment.


Assuntos
Transferência Genética Horizontal , Ferro , Peróxidos , Peróxidos/química , Ferro/química , Purificação da Água/métodos , Escherichia coli/efeitos dos fármacos , Escherichia coli/genética , Farmacorresistência Bacteriana/genética , Desinfecção/métodos , Sulfatos/química , Antibacterianos/farmacologia , Antibacterianos/química , Bacillus/genética , Bacillus/efeitos dos fármacos , Bacillus/metabolismo
9.
BMC Oral Health ; 24(1): 458, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622548

RESUMO

BACKGROUND: Various methods, chemical and physical, disinfect dental impressions. Common chemicals include 1% Sodium Hypochlorite and 2% glutaraldehyde, while UV radiation is a prevalent physical method. Few studies compare their effects on dimensional stability in polyether impressions. This study aims to assess such stability using different disinfection methods. Therefore, this study was planned to evaluate the dimensional stability of polyether impression material using different disinfection methods. METHODS: This in vitro study compared the effects of chemical disinfectants (1% Sodium Hypochlorite and 2% glutaraldehyde) and UV irradiation on the dimensional stability of polyether impression material. Groups A, B, C, and D, each with ten samples (N = 10), were studied. Group A was untreated (control). Group B was treated with 2% glutaraldehyde for 20 min, Group C with 1% Sodium Hypochlorite for 20 min, and Group D with UV rays for 20 min. A pilot milling machine drill was used to make four parallel holes labeled A, B, C, and D in the anterior and premolar regions from right to left. After sequential drilling, four implant analogs were positioned using a surveyor for accuracy. Ten open-tray polyether impressions were made and treated as described in the groups, followed by pouring the corresponding casts. Distortion values for each disinfection method were measured using a coordinate measuring machine capable of recording on the X- and Y-axes. RESULTS: A comprehensive analysis was conducted using the one-way ANOVA test for distinct groups labeled A, B, C, and D, revealing significant differences in the mean distances for X1, X2, X4, X5, and X6 among the groups, with p-values ranging from 0.001 to 0.000. However, no significant differences were observed in X3. Notably, mean distances for the Y variables exhibited substantial differences among the groups, emphasizing parameter variations, with p-values ranging from 0.000 to 0.033. The results compared the four groups using the one-way ANOVA test, revealing statistically significant distance differences for most X and Y variables, except for X3 and Y4. Similarly, post-hoc Tukey's tests provided specific pairwise comparisons, underlining the distinctions between group C and the others in the mean and deviation distances for various variables on both the X- and Y-axes. CONCLUSIONS: This study found that disinfection with 1% sodium hypochlorite or UV rays for 20 min maintained dimensional stability in polyether impressions.


Assuntos
Desinfetantes , Desinfecção , Humanos , Desinfecção/métodos , Glutaral , Hipoclorito de Sódio , Materiais para Moldagem Odontológica , Técnica de Moldagem Odontológica
10.
PLoS One ; 19(4): e0302258, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38626152

RESUMO

Effective surface disinfection is crucial for preventing the spread of pathogens in hospitals. Standard UltraViolet-C (UV-C) lamps have been widely used for this purpose, but their disinfection efficiency under real-world conditions is not well understood. To fill this gap, the influence of the power of the ultraviolet radiator, source-sample distance, and exposure time on the performance of UV-C lamps against Escherichia coli and Staphylococcus epidermidis were experimentally determined in the laboratory and hospital. The obtained results showed that the UV irradiance and, thus, the UV-C disinfection efficiency decreased significantly at distances greater than 100 cm from the UV-C lamp. Moreover, increasing the total power of the radiators does not improve the performance of UV-C lamps under real conditions. The UV-C disinfection efficiency greater than 90% was achieved only under laboratory conditions at a close distance from the UV-C lamp, i.e., 10 cm. These findings provide novel insights into the limitations of UV-C lamps in real-world conditions and highlight the need for more effective disinfection strategies in hospitals.


Assuntos
Escherichia coli , Raios Ultravioleta , Desinfecção/métodos
11.
World J Urol ; 42(1): 252, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38652324

RESUMO

BACKGROUND: To prevent infectious complications after transrectal ultrasound-guided prostate biopsy (TRUS-PB), some studies have investigated the efficacy of rectal disinfection using povidone-iodine (PI) and antibiotic prophylaxis (AP). OBJECTIVE: To summarize available data and compare the efficacy of rectal disinfection using PI with non-PI methods prior to TRUS-PB. EVIDENCE ACQUISITION: Three databases were queried through November 2023 for randomized controlled trials (RCTs) analyzing patients who underwent TRUS-PB. We compared the effectiveness of rectal disinfection between PI groups and non-PI groups with or without AP. The primary outcomes of interest were the rates of overall infectious complications, fever, and sepsis. Subgroups analyses were conducted to assess the differential outcomes in patients using fluoroquinolone groups compared to those using other antibiotics groups. EVIDENCE SYNTHESIS: We included ten RCTs in the meta-analyses. The overall rates of infectious complications were significantly lower when rectal disinfection with PI was performed (RR 0.56, 95% CI 0.42-0.74, p < 0.001). Compared to AP monotherapy, the combination of AP and PI was associated with significantly lower risk of infectious complications (RR 0.54, 95% CI 0.40-0.73, p < 0.001) and fever (RR 0.47, 95% CI 0.30-0.75, p = 0.001), but not with sepsis (RR 0.49, 95% CI 0.23-1.04, p = 0.06). The use of fluoroquinolone antibiotics was associated with a lower risk of infectious complications and fever compared to non-FQ antibiotics. CONCLUSION: Rectal disinfection with PI significantly reduces the rates of infectious complications and fever in patients undergoing TRUS-PB. However, this approach does not show a significant impact on reducing the rate of sepsis following the procedure.


Assuntos
Anti-Infecciosos Locais , Desinfecção , Povidona-Iodo , Próstata , Reto , Humanos , Povidona-Iodo/uso terapêutico , Povidona-Iodo/administração & dosagem , Masculino , Desinfecção/métodos , Anti-Infecciosos Locais/uso terapêutico , Anti-Infecciosos Locais/administração & dosagem , Próstata/patologia , Antibioticoprofilaxia/métodos , Biópsia Guiada por Imagem/métodos , Neoplasias da Próstata/patologia
12.
Sci Total Environ ; 927: 172257, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38608912

RESUMO

Waterborne pathogens threaten 2.2 billion people lacking access to safely managed drinking water services, causing over a million annual diarrheal deaths. Individuals without access to chlorine reagents or filtration devices often resort to do-it-yourself (DIY) methods, such as boiling or solar disinfection (SODIS). However, these methods are not simple to implement. In this study, we introduced an innovative and easily implemented disinfection approach. We discovered that immersing aluminum foil in various alkaline solutions produces alkali-treated aluminum foil (ATA foil) that effectively adsorbs Escherichia coli (E. coli), Salmonella, and Acinetobacter through the generated surface aluminum hydroxide. For example, a 25 cm2 ATA foil efficiently captures all 104E. coli DH5α strains in 100 mL water within 30 min. Using a saturated suspension of magnesium hydroxide, a type of fertilizer, as the alkaline solution, the properties of the saturated suspension eliminate the need for measuring reagents or changing solutions, making it easy for anyone to create ATA foil. ATA foils can be conveniently produced within mesh bags and placed in household water containers, reducing the risk of recontamination. Replacing the ATA foil with a foil improves the adsorption efficiency, and re-immersing the used foil in the production suspension restores its adsorption capacity. Consequently, ATA foil is an accessible and user-friendly alternative DIY method for underserved communities. Verification experiments covering variations in the water quality and climate are crucial for validating the efficacy of the foil. Fortunately, the ATA foil, with DIY characteristics similar to those of boiling and SODIS, is well-suited for testing under diverse global conditions, offering a promising solution for addressing waterborne pathogens worldwide.


Assuntos
Desinfecção , Água Potável , Purificação da Água , Água Potável/microbiologia , Água Potável/química , Desinfecção/métodos , Purificação da Água/métodos , Microbiologia da Água , Abastecimento de Água
13.
PLoS One ; 19(4): e0300355, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38573892

RESUMO

In recent decades, minimally invasive surgery has become the favoured surgical technique, with increasing utilisation of robotic surgery to enhance patient outcomes. However, the design complexity of surgical robotic instruments can pose challenges in maintaining adequate cleaning, disinfection and sterilisation-particularly of the device's interior. In our hospital, robotic instruments are reused for a maximum of ten successive patients, following the manufacturer's guidelines. To the best of our knowledge, neither the manufacturer nor ISO standards have specified any methods to determine the sterility of robotic instruments after cleaning, disinfection and sterilisation procedures. In a small pilot study, we used a locally developed protocol to evaluate the sterility of 20 da Vinci SI robotic instruments, with the aim of determining whether the recommended cleaning, disinfection and sterilisation process is adequate to achieve safe usage in subsequent patients. None of the 20 instruments showed viable micro-organisms, therefore the robotic instruments were considered sterile, and suitable for re-use. We recommend our protocol to other hospitals, to be used as an essential control element in the assessment of their unique reprocessing technique for robotic instruments.


Assuntos
Infertilidade , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Projetos Piloto , Desinfecção/métodos , Procedimentos Cirúrgicos Minimamente Invasivos
14.
Food Microbiol ; 121: 104516, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38637078

RESUMO

Oxidation-reduction potential (ORP) is commonly used as a rapid measurement of the antimicrobial potential of free chlorine during industrial fresh produce washing. The current study tested the hypothesis that ORP can act as a "single variable" measurement of bacterial (vegetative and endospores) inactivation effectiveness with free chlorine irrespective of the water pH value. This situation has on occasion been assumed but never confirmed nor disproven. Chlorine-dosed pH 6.5 and 8.5 phosphate buffer solutions were inoculated with Escherichia coli (E. coli), Listeria innocua (L. innocua), or Bacillus subtilis (B. subtilis) endospores. ORP, free chlorine (FC), and log reduction were monitored after 5 s (for E. coli and L. innocua) and up to 30 min (for B. subtilis spores) of disinfection. Logistic and exponential models were developed to describe how bacteria reduction varied as a function of ORP at different pH levels. Validation tests were performed in phosphate buffered pH 6.5 and 8.5 cabbage wash water periodically dosed with FC, cabbage extract and a cocktail of Escherichia coli O157:H7 (E. coli O157:H7) and Listeria monocytogenes (L. monocytogenes). The built logistic and exponential models confirmed that at equal ORP values, the inactivation of the surrogate strains was not consistent across pH 6.5 and pH 8.5, with higher reductions at higher pH. This is the opposite of the well-known free chlorine-controlled bacterial inactivation, where the antibacterial effect is higher at lower pH. The validation test results indicated that in the cabbage wash water, the relationship between disinfection efficiency and ORP was consistent with the oxidant demand free systems. The study suggests that ORP cannot serve as a reliable single variable measurement to predict bacterial disinfection in buffered systems. When using ORP to monitor and control the antibacterial effectiveness of the chlorinated wash water, it is crucial to take into account (and control) the pH.


Assuntos
Escherichia coli O157 , Listeria monocytogenes , Listeria , Desinfecção/métodos , Cloro/farmacologia , Cloro/análise , Contaminação de Alimentos/análise , Microbiologia de Alimentos , Oxidantes , Contagem de Colônia Microbiana , Manipulação de Alimentos/métodos , Cloretos , Oxirredução , Água/química , Antibacterianos , Concentração de Íons de Hidrogênio , Fosfatos
15.
Food Microbiol ; 121: 104523, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38637085

RESUMO

This study investigated the fungicidal efficiency and mechanism of action of dielectric barrier discharge cold atmosphere plasma (DBD-CAP) in inactivating Aspergillus niger (A. niger) spores. The disinfection efficacy and quality of dried jujube used as the processing application object were also studied. The results indicated that the Weibull + Tail model performed better for spore inactivation curves at different voltages among various treatment times, and the spore cells were reduced by 4.05 log (cfu/mL) in spores suspension at 70 kV after 15 min of treatment. This disinfection impact was further supported by scanning electron microscope (SEM) and transmission electron microscopy (TEM) images, which showed that the integrity of the cell membrane was damaged, and the intracellular content leaked out after DBD-CAP treatment. Elevated levels of reactive oxygen species (ROS) during the treatment increased the relative conductivity of cells, and leakage of nucleic acids and proteins further supported the disinfection impact. Additionally, the growth and toxicity of surviving A. niger spores after treatment were also greatly reduced. When DBD-CAP was applied to disinfecting dried jujube, the spore number exhibited a 2.67 log cfu/g reduction after treatment without significant damage observed onto the quality (P > 0.05).


Assuntos
Aspergillus , Gases em Plasma , Ziziphus , Aspergillus niger , Gases em Plasma/farmacologia , Desinfecção/métodos
16.
Sci Rep ; 14(1): 6722, 2024 03 20.
Artigo em Inglês | MEDLINE | ID: mdl-38509265

RESUMO

An emerging intervention for control of airborne-mediated pandemics and epidemics is whole-room far-UVC (200-235 nm). Laboratory studies have shown that 222-nm light inactivates airborne pathogens, potentially without harm to exposed occupants. While encouraging results have been reported in benchtop studies and in room-sized bioaerosol chambers, there is a need for quantitative studies of airborne pathogen reduction in occupied rooms. We quantified far-UVC mediated reduction of aerosolized murine norovirus (MNV) in an occupied mouse-cage cleaning room within an animal-care facility. Benchtop studies suggest that MNV is a conservative surrogate for airborne viruses such as influenza and coronavirus. Using four 222-nm fixtures installed in the ceiling, and staying well within current recommended regulatory limits, far-UVC reduced airborne infectious MNV by 99.8% (95% CI: 98.2-99.9%). Similar to previous room-sized bioaerosol chamber studies on far-UVC efficacy, these results suggest that aerosolized virus susceptibility is significantly higher in room-scale tests than in bench-scale laboratory studies. That said, as opposed to controlled laboratory studies, uncertainties in this study related to airflow patterns, virus residence time, and dose to the collected virus introduce uncertainty into the inactivation estimates. This study is the first to directly demonstrate far-UVC anti-microbial efficacy against airborne pathogens in an occupied indoor location.


Assuntos
Doenças Transmissíveis , Infecções por Coronavirus , Norovirus , Vírus , Animais , Camundongos , Raios Ultravioleta , Ambiente Controlado , Desinfecção/métodos
17.
Sci Rep ; 14(1): 5151, 2024 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-38431740

RESUMO

Chytridiomycosis caused by the fungal pathogen Batrachochytrium dendrobatidis (Bd) is pushing amphibians towards extinction. Whilst mitigation methods were suggested a decade ago, we lack field trials testing their efficacy. We used the agrochemical fungicide, tebuconazole, to treat Bd infected breeding waterbodies of an endangered species that is highly susceptible to the fungus. Just two applications of tebuconazole led to a significant reduction in infection loads in the vast majority of sites, and at six sites the disinfection remained one/two-years post-application. Tebuconazole values drastically decreased in the waterbodies within a week after application, with no significant effects on their hydrochemical and hydrobiological characteristics. Although the use of chemicals in natural populations is undesirable, the growing existential threat to amphibians all over the world indicates that effective interventions in selected populations of endangered species are urgently needed.


Assuntos
Quitridiomicetos , Micoses , Animais , Desinfecção , Melhoramento Vegetal , Anfíbios/microbiologia , Micoses/veterinária , Micoses/microbiologia , Espécies em Perigo de Extinção , Batrachochytrium
18.
AORN J ; 119(4): 275-282, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38536400

RESUMO

There are several steps involved when performing high-level disinfection (HLD) of semicritical devices. The recently updated AORN "Guideline for manual high-level disinfection" provides perioperative nurses with evidence-based best practices for performing safe and effective HLD of reusable semicritical items. The guideline also addresses preventing injury to patients and health care workers associated with the handling of high-level disinfectants. This article provides an overview of the guideline and discusses recommendations for selection of a processing method, sterile processing areas, preparation of items for HLD, preparation of high-level disinfectants, manual HLD, drying and storage of items after HLD, and processing records. It also includes a scenario that illustrates specific concerns related to performing quality tests on high-level disinfectant solutions. Perioperative nurses should review the guideline in its entirety and apply the recommendations when performing manual HLD.


Assuntos
Desinfetantes , Desinfecção , Humanos , Desinfecção/métodos , Pessoal de Saúde
19.
BMC Med Educ ; 24(1): 246, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38448923

RESUMO

BACKGROUND: Despite the updated guidelines on dental impression disinfection protocols during the COVID-19 pandemic, adherence to such procedures has not been studied among dental health professionals in Saudi Arabia. Understanding DHPs' knowledge, attitudes, and practices regarding COVID-19 is crucial in assessing a willingness to adhere to the recommendations provided by health authorities in mitigating the spread of COVID-19 via dental impressions impacting patient safety and infection control measures. Hence, this study aimed to assess dental health professionals' (DHPs) knowledge, attitudes, and practices (KAP) toward dental impression disinfection protocol during the COVID-19 pandemic in Saudi Arabia. METHODS: A cross-sectional study using an online survey was conducted from 14 December 2022 to 21 March 2023 among practicing dentists, dental assistants (DA), dental laboratory technicians (DT), and dental hygienists in Saudi Arabia. A validated and reliable questionnaire that consisted of 38 items along with demographic variables was prepared to collect the data. Using Google Forms, a questionnaire link was prepared and shared on the social media platforms of DHPs in Saudi Arabia. A descriptive analysis was conducted to report the percentages and frequencies. The mean knowledge, attitude, and practice scores were analyzed using an Independent t-test, ANOVA, and Pearson's correlation tests. RESULTS: A total of 718 DHPs voluntarily participated in the survey. Most of the DHPs exhibited average knowledge 392 (54.6%), neutral attitudes 393(54.7%), and adequate 549 (76.5%) practice towards dental impression disinfection protocol. The mean knowledge score differed significantly across nationality (p = 0.013), type of DHPs (p < 0.001), qualification (p = 0.045), and experience (p = 0.028) of the study participants. Significant differences in attitude towards impression disinfection were observed in different age groups (p = 0.002), qualifications (p = 0.015), and experiences (p = 0.024) of the DHPs. Similarly, practice varied across different age groups (p = 0.010), nationality (p = 0.013), type of DHPs (p = 0.019), qualification (p = 0.044), experience (p = 0.041), and COVID-19 Infection (p = 0.006). Moreover, a significant positive correlation between knowledge-attitude (r = 0.258, p < 0.01), knowledge-practice (r = 0.283, p < 0.01), and attitude-practice (r = 0.196, p < 0.01) was observed. CONCLUSION: DHPs considered in this study demonstrated average knowledge and attitudes toward impression disinfection, requiring improvement through continuous dental education and training. However, they displayed acceptable dental impression disinfection practices during the COVID-19 pandemic. It is highly recommended that continuing education programs should mainly reinforce the knowledge of sodium hypochlorite, iodophor, and phenolics and their concentrations to be used as an impression disinfectant. Additionally, it should focus on techniques of disinfecting elastomeric, hydrocolloid, zinc oxide and eugenol, and impression compound materials to mitigate the spread of COVID-19 based on Saudi ministry of health guidelines.


Assuntos
COVID-19 , Desinfecção , Humanos , COVID-19/prevenção & controle , Estudos Transversais , Arábia Saudita , Conhecimentos, Atitudes e Prática em Saúde , Pandemias/prevenção & controle
20.
Environ Sci Technol ; 58(13): 6030-6038, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38517061

RESUMO

Increasing radical yields to reduce UV fluence requirement for achieving targeted removal of micropollutants in water would make UV-based advanced oxidation processes (AOPs) less energy demanding in the context of United Nations' Sustainable Development Goals and carbon neutrality. We herein demonstrate that, by switching the UV radiation source from conventional low-pressure UV at 254 nm (UV254) to emerging Far-UVC at 222 nm (UV222), the fluence-based concentration of HO• in the UV/peroxydisulfate (UV/PDS) AOP increases by 6.40, 2.89, and 6.00 times in deionized water, tap water, and surface water, respectively, with increases in the fluence-based concentration of SO4•- also by 5.06, 5.81, and 55.47 times, respectively. The enhancement to radical generation is confirmed using a kinetic model. The pseudo-first-order degradation rate constants of 16 micropollutants by the UV222/PDS AOP in surface water are predicted to be 1.94-13.71 times higher than those by the UV254/PDS AOP. Among the tested water matrix components, chloride and nitrate decrease SO4•- but increase HO• concentration in the UV222/PDS AOP. Compared to the UV254/PDS AOP, the UV222/PDS AOP decreases the formation potentials of carbonaceous disinfection byproducts (DBPs) but increases the formation potentials of nitrogenous DBPs.


Assuntos
Poluentes Químicos da Água , Purificação da Água , Água , Fotólise , Poluentes Químicos da Água/análise , Peróxido de Hidrogênio , Oxirredução , Raios Ultravioleta , Desinfecção
SELEÇÃO DE REFERÊNCIAS